+86 18068001229 Ibyiza n'ibibi bya transfoma zikoreshwa mu mazi

IbyizaEse?
1.Gukonjesha no Gutwika Ubushyuhe mu buryo BwizaEse?
Transformer ikoreshwa mu mavutaikoresha amavuta akingira ubushyuhe kugira ngo ifate kandi yohereze ubushyuhe neza. Ubushobozi bwinshi bw'ubushyuhe bw'amavuta hamwe n'ubushobozi bwo gutwara ubushyuhe bituma ikora neza mu gihe cy'imitwaro iremereye, bigatuma iba nziza cyane mu gukoresha ingufu nyinshi z'amashanyarazi.
2.Imiterere myiza yo gukingira ubushyuheEse?
Amavuta ya Transformer akora nk'uburyo bukomeye bwo gukoresha amashanyarazi, akarinda kwangirika kw'amashanyarazi no kwangirika kw'amashanyarazi. Yinjira mu bikoresho bikingira amashanyarazi nk'impapuro, yongera igihe cyabyo cyo kuramba no kongera igihe cyo kubaho kwa transformer.
3.Uburyo bwo Kugabanya IkiguziEse?
Ibiciro byo mu nganda bya mbere biri hasi ugereranije n'ibiciro Transformateur yo mu bwoko bwumyes, kandi kuzigama mu mikorere bituruka ku mikorere myiza cyane (98–99%) no kugabanuka kw'igihombo cy'ingufu. Amafaranga yo kubungabunga ashobora gucungwa hakoreshejwe uburyo busanzwe nko gupima amavuta no kuyayungurura.
4.Ubushobozi bwo kuremerera cyaneEse?
Ubushyuhe bw'amavuta butuma habaho ubwinshi bw'ibicuruzwa by'agateganyo bidafite izamuka rikomeye ry'ubushyuhe, bigatuma izi transformateur ziba nziza mu guhindura imitwaro y'inganda.
5.Igihe kirekire cyo gukoraEse?
Iyo ivuguruwe neza, transfoma zikoreshwa mu mazi zishobora gukora neza mu gihe cy'imyaka 20-40. Imiterere y'amavuta yo kwivura ubwayo (urugero, gukora gaze mu gihe cyo kubona amakosa) yongera imbaraga zo kuramba
ImbogamiziEse?
1.Ingaruka z'inkongi n'ibisasuEse?
Amavuta y'ubutare afite ubushyuhe bwa dogere selisiyusi zigera kuri 140, bigatuma habaho ibyago byo gutwika mu gihe cy'impanuka. Inkuta z'umuriro n'uburyo bwo kuzimya amavuta ni ngombwa, bigatuma uburyo bwo kuyashyiraho burushaho kuba bwiza.
2.Ibibazo ku bidukikijeEse?
Amavuta asohoka ashobora kwanduza ubutaka n'amazi, bigasaba gufunga neza no gukoresha uburyo bwihariye bwo kuyajugunya. Amavuta ya ester y'ubukorano ni meza ariko arahenze cyane.
3.Ibisabwa ku kubungabungaEse?
Gusuzuma buri gihe urugero rw'amavuta, gupima ubushuhe, no gusesengura gazi (urugero, gusesengura gazi yashongeshejwe) ni ngombwa. Amavuta ashaje agomba gusimburwa cyangwa kuyungururwa.
4.Ubunini n'UburemereEse?
Ibigega bya peteroli n'uburyo bwo gukonjesha bituma izi transformateur ziba nini kandi ziremereye, bigatuma zikoreshwa mu bice bito cyane nko mu nyubako zo mu mijyi.
5.Ibibazo by'Ubukonje mu Mihindagurikire y'IkirereEse?
Mu bushyuhe buke, ubushyuhe bw'amavuta buriyongera, bigatuma ubushyuhe budakwirakwira. Amavuta akozwe muri silikoni ashobora gukenerwa, bigatuma ikiguzi cyo gukora kiyongera.
Kugereranya na Transformers zo mu bwoko bwumyeEse?
- Ese?Gukora neza: Transformateur zicukurwa mu mavuta zirusha izumutse ubwoko bw'amashanyarazi bitewe n'ubukonje bwinshi n'igihombo gito cy'ingufu.
- Ese?Umutekano: Ubwoko bwumye ntibushobora gushya kandi bukwiriye ahantu ho mu nzu cyangwa mu mijyi ariko ntibukora neza kandi buhendutse igihe kirekire.
- Ese?Porogaramu: Transformateur zicukurwa muri peteroli ziganza insinga z'amashanyarazi n'inganda, mu gihe ubwoko bw'umukungugu bukunda gukoreshwa ahantu hashobora kwangirika
UmwanzuroEse?
Transformateur zicukurwa mu mazutu zirakora neza cyaneporogaramu zikoresha ingufu nyinshi kandi zifite amashanyarazi menshibitewe n’imikorere yabyo, kuramba kwayo, no kugabanya ikiguzi. Ariko, imbogamizi nk’inkongi y’umuriro n’ingaruka ku bidukikije bisaba kugabanya ibiyobyabwenge binyuze mu ngamba zigezweho zo kwirinda no gukoresha peteroli ikoze mu buryo bw’ubukorano. Ku duce duto cyangwa duto tworoshye ibidukikije, transformateur z’ubwoko bwumye zitanga ubundi buryo bufatika nubwo amafaranga menshi atangwa mbere.