Mu iterambere ry’ikoranabuhanga rya smart grid, transformers za JZP zifite ibice bitatu (PMTs) zagaragaye nk'igisubizo gihindura umukino kugira ngo zigire umusaruro mwiza. Gukwirakwiza Ingufu. Guhuza imiterere mito n'ubuhanga bugezweho, izi "hubs z'ingufu zigezweho" zisobanura neza uburyo zizewe kandi zirambye. Reka turebe imiterere igoye ya PMTs za JZP maze turebe ibitangaza by'ikoranabuhanga bitanga imbaraga mu bikorwa remezo bigezweho.

1. ​Ubwubatsi bwa Modular: Akaremangingo k'Ingufu k'Ubwenge​
PMT za JZP zikoresha igishushanyo mbonera cya "SmartCube" gishya gihuza sisitemu eshatu z'ingenzi mu gikari kimwe, kidahura n'ikirere:

Icyumba gifite Voltage nyinshi: Ibikoresho byo gufunga imizigo bifite icyuma gifunga imizigo gifite SF6 gaz insulation
Umuyoboro wa Transformer: Umuyoboro wa alloy uteye imbere ugabanya igihombo cy'ingufu
Ikwirakwizwa rya Voltage Nto: Igenzura rya logic rishobora gutegurwa hamwe n'ihuza rya IoT

Iyi miterere igabanya igihe cyo kuyishyiraho ho 60% ugereranije n'igihe gisanzwe cyo kuyishyiraho kandi ikaba igabanyaho 40% by'igihe cyo kuyishyiraho.

2. Sisitemu ifite ingufu nyinshi: Ubuhanga bwo kwirinda impanuka
2.1 Sisitemu yo Kurinda Imbunda Zivanze
​Vacuum Interrupter: Ifite amanota ya 63kA short-circuit current hamwe n'imikorere 10.000 ya mekanike
Fuse zo Kumenya Ibintu Bibiri: Gukurikirana ubushyuhe n'umuvuduko w'amazi kugira ngo birinde mbere yo gukoresha imbaraga
Ingufuri za Mechanical Interlocks: Zirinda ingufu ziterwa n'impanuka mu gihe cyo kubungabunga
2.2 ​Amabati y'ubwenge​
Utwuma dukingira amashanyarazi twa polymer: Turwanya imbaraga za 100kV/m
​RFID Tagging: Ifasha mu kugenzura indwara zidaterwa n'icyorezo
Kwisukura: Bigabanya 75% by'ibura ry'ibikoresho bitewe n'umwanda

3. ​Ishingiro rya Transformer: Ubushobozi bwa Magnetic

3.1 Ikoranabuhanga rya Aloi y'ubururu

Igipimo

Ibisobanuro bya JZP

Ibipimo ngenderwaho by'inganda

Igihombo cy'ibanze (W/kg)

≤0.12 @50Hz

0.35

Ubucucike bwa Magnetic Flux

1.45T

1.5T

Urwego rw'urusaku

≤45dB(A)

≤55dB(A)

Igishushanyo mbonera cy’inkingi y’amaguru atatu gigabanya igihombo cy’umuyoboro w’amazi ku kigero cya 40% binyuze mu nzira nziza zo guhindagurika kw’amazi.

3.2 ​Matrix yo Gukonjesha Ikora​
Ibikoresho bihindura icyiciro (PCM) Ibice: Bikura ubushyuhe bwa 300kJ/m³
Amababa atera imiyaga: Yongera ubushobozi bwo gukurura imiyoboro karemano ku kigero cya 250%.
Uburyo bwo gukonjesha bwa Hybrid: Hindura byikora hagati y'ingufu zituruka ku gukonjesha/imirasire hashingiwe ku mutwaro


4. Sisitemu y'amashanyarazi make: Ubwenge buhuza ikoranabuhanga n'ikoranabuhanga

Ingufu zitanga imbaraga
Indishyi ya VAR idahinduka: Igumana PF >0.98 mu mikorere yose y'umutwaro
Kugabanya Harmonic: Akayunguruzo ka 4 gahagarika harmonic kugeza kuri 25
Kurinda ibura ry'amashanyarazi: Kwimura UPS mu buryo butagoramye muri

5. ​Ipaki yo kwihanganira ibidukikije​
5.1 Uburinzi bw'urwego rwa gisirikare
Igipimo cya IP68/IP69K: Yarokotse kwibira mu mazi ya metero 2 mu gihe cy'iminota 30
Ubudahangarwa bw'ibihu by'umunyu: Yatsinze ikizamini cya ASTM B117 cy'amasaha 1000
EMI Shield: 5.2 Ibikoresho Bitangiza ibidukikije​
Amavuta ya Dielectric ashobora kubora: 100% ester ishingiye ku bimera
Agakoresho ka aluminiyumu gashobora kongera gukoreshwa: 98% by'ibikoresho bishobora kugaruzwa
Igishushanyo mbonera cy'amazi asohoka nta mavuta: Gikoresha uburyo bwo kubika azote ifunze neza

6. Ibiranga guhuza ikoranabuhanga rya Smart Grid​
Interineti y'Ingufu Zikwirakwizwa (DER): Ishyigikira guhuza imirasire y'izuba na PV/ububiko
Kugarura Voltage Ihindagurika (DVR): Igumana ubudahinduka bwa Voltage ± 1%
Inzira yo Gusubiza Ibikenewe: Yitabira amasoko y'inyongera ya serivisi

Inkuru z'Intsinzi mu Gukoresha Porogaramu
Udukoresho duto tw’amashanyarazi mu Mujyi: Gutanga ingufu ku mazu arenga 15,000 mu Mujyi Urambye wa Dubai
Ibisubizo by'Ikigo cy'Amakuru: 99.999% by'igihe cyo gukora ku bigo bya AWS muri Singapuru
Amashanyarazi yo kuri gari ya moshi: Guhindura 25kV AC/DC kuri gari ya moshi zitwara abagenzi zikora 300km/h

Vugana na JZP Uyu munsi​
Tegura Ejo Hazaza Hawe Hazaza Ukoresheje Ibisubizo by'Ikoranabuhanga bya Transformer
Ubufasha mu bya tekiniki: +86 16655239333

Ibisobanuro byose bya tekiniki byubahiriza amahame ya IEC 60076-11 na UL 1561.
Guteza imbere ikoranabuhanga ry'ejo hazaza uyu munsi – JZP Power Solutions