+86 18068001229 01
Transformer ifite inkingi imwe—25 kVA
Ibisobanuro by'igicuruzwa
JZP irakomeye mu gukora transformateur za ANSI/IEEE/UL, igaragaza ubuhanga n'ubuhanga butangaje ku masoko ya Amerika y'Amajyaruguru n'Amajyepfo. Batanga transformateur 25 kVA zifite inkingi imwe, zishobora gutegurwa, gukorwa, no guhindurwa kugira ngo zihuze n'amahame mpuzamahanga atandukanye. Icyerekezo cya JZP cyo kuba indashyikirwa gituma baba umufatanyabikorwa wizewe ku bisabwa byose bya transformateur muri Amerika no hanze yayo.

Transformer imwe ya 25kVA 19.92kV
DL-25/19.92/0.24(0.12), ni transformer yihariye ifite inkingi imwe.
Transformateur ifite 25 kVA ifite inkingi imwe ikoresha ibikoresho byiza byo kuzunguruka bya aluminiyumu haba ku bice byayo bifite voltage nyinshi n'iziciriritse, bigatuma habaho imikorere myiza kandi yizewe. Ifite impedance value ya 2%, ifite Vector group ya Ii0 na polarity igabanya imikorere, yongera imikorere yayo.
Umuvuduko mwinshi wa transformateur ufite urwego rushanu rutandukanye rwo kugenzura amashanyarazi, utanga ubushobozi bwo gukora ibintu bitandukanye, mu gihe umuvuduko wa 19.92kV ± 2×2.5% utuma habaho umutekano uhamye ndetse no mu gihe cy'ihindagurika.

25kVA 7.2 (12.47)kV/4.8 (8.32)kV Transformer y'icyiciro kimwe
Transformateur ya 25 kVA ifite inkingi imwe ifite imiterere ibiri ifite ingufu nyinshi. Ibi bituma habaho guhitamo neza ingufu nyinshi kuva kuri 7.2kV cyangwa 4.8 kV, ijyanye neza n'ibikenewe mu bikoresho bitandukanye, itanga ubushobozi bwo gukora ibintu bitandukanye.
Transformateur ikoresha sisitemu yo gukonjesha ya ONAN ikora neza, ikongerwamo amavuta y'ubutare 45# adafite PCB, igenzura umutekano n'inshingano zo kubungabunga ibidukikije.
Ikoresheje itsinda ryizewe rya vektori ya Ii6 hamwe na polarity y’inyongera, transformateur ni yo ifite imikorere myiza kandi yizewe. Ibikoresho by'ingenzi birimo icyuma kimwe gifite voltage nyinshi, ibyuma bitatu bifite voltage nke, icyuma kimwe gifite voltage ebyiri, icyuma kimwe cyo kugabanya umuvuduko, icyuma kimwe cya H2, ibyuma bibiri by'umuringa, ibyuma bitatu byo gutwikira, ibyuma bibiri byo gushyigikira, ibyuma bibiri byo kuzamura, n'udupfundikizo 6, bigaragaza imiterere yacyo igezweho n'ubushobozi bwacyo.

Transformer imwe ya 25kVA 17.32kV
Iyi transformateur ifite voltage y'ibanze ya 17.32 kV na voltage y'inyongera ya 230V, yakozwe neza kugira ngo ihuze n'ibyo umukiriya akeneye byihariye.
Kubera ko ifite umuringa uzunguruka mu mutima wayo, iyi transformateur ihamya imikorere myiza n'ubwizerwe. Ikora ku muvuduko wa 50 Hz kandi ifite itsinda rya Vector rya Ii0 rifite polarity y'inyongera, ituma ihuzwa neza mu buryo butandukanye bw'ingufu.
Transformateur ifite urwego rwo kugenzura rwa 17.32kV±2×2.5%, ituma ingufu z'amashanyarazi zisohoka neza kandi zidahindagurika ndetse no mu bihe bitandukanye by'umutwaro.

Baza ubu ngubu!
Ku bibazo bijyanye n'ibicuruzwa byacu cyangwa urutonde rw'ibiciro, tubwire imeri yawe maze tuzakwandikira mu masaha 24.