+86 18068001229 01
Transformer ifite 2500kVA ifite ibice bitatu
Ibisobanuro by'igicuruzwa
JZP Transformer ni ikigo cy’umwuga mu gukora transformers gifite urutonde rwa UL n’ibyemezo by’urwego rw’amashanyarazi kugeza kuri 44kV, gitanga ubwoko bwinshi bwa transformers zemewe na UL. Buri mwaka, twohereza ibihumbi by’izi transformers muri Leta Zunze Ubumwe za Amerika na Kanada. Kubera ko dufite ubumenyi mu bya IEEE/ANSI, CSA, DOE, NEMA, n’andi mabwiriza, itsinda ryacu rigenzura ko byujuje ibisabwa bitandukanye mu mategeko. Uretse icyemezo cya UL, dufite kandi impamyabumenyi za CSA, MF, CESI, na raporo z’ibizamini bya SGS by’abandi. Dufite uburambe bwinshi mu mishinga, twumva ko buri mushinga ufite ibisabwa byihariye. Niyo mpamvu dutanga transformers zishobora guhindurwa, zituma habaho impinduka ku muvuduko w’amashanyarazi, ubushobozi, uburyo bwo guhuza, n’igishushanyo cyihariye kugira ngo bihuze neza n’ibyo ukeneye. Transformer ifite 2500 kVA ishobora guhindurwa kugira ngo ihuze n’ibyo ukeneye mu mushinga wawe. Vugana na Daelim Transformer uyu munsi kugira ngo ubone urupapuro rw’ibipimo, ibishushanyo, n’ibiciro bya transformer ifite 2500 kVA.
01020304050607
| Ibisobanuro bya Transformer ya 2500 kVA (2.5 MVA) | |||
| Icyiciro | Icyiciro cya gatatu | Std. | ANSI/IEEE Std C57 na DOE Std 2016 |
| Ingano y'ingufu | 2000kVA (2.5MVA) | Gushyiraho | Inzira y'imbere/iy'inyuma idakora neza |
| Gushyiraho | Pad Mount | Inshuro | 60Hz |
| Umuvuduko wa HV | 13200/6720V | Agakoresho ko guhindura kanda | Imyanya 5 |
| Voltage ya LV | 600/347V | Ubushobozi bw'amazi | 1600L |
| NI IMODOKA ITE? | 95 kV | Uburemere bwose | 7000kG |
| IMODOKA YA LV | 30 kV | Nta gutakaza umutwaro | 2500W |
| Itsinda rya Vector | Mun0 | Ku igabanuka ry'umutwaro | 15000W |
| Uburyo bwo gukonjesha | KOMEZA UTUZA KANDI URUKUNDO | Impedance | 5.75% |
| Ibikoresho byo gupfunyika | Aluminium | Ibara ry'irangi | Icyatsi kibisi cya Munsell |
| Amazi yo gukingira | Amavuta y'ibimera ashobora kubora | Ubushobozi bwo kwiyongera k'ubushyuhe kuri 65℃ | 2500 kVA |
| Ishusho y'ibanze | Icyiciro cya gatatu cy'inkingi ya gatanu | Imodoka zikoresha imbaraga (Abafana) | Nta na kimwe |

Ibiranga Transformer ya 2500 kVA
Transformateur ya ZGSL-H-2500/13.2-0.6 ifite ingufu zingana na 2500 kVA (2.5 MVA). Transformateur ya 2500 kVA ifite ingufu zingana na 13.2/7.62 kV ifite umurongo wa Wye, H0 grounding ifite ingufu nyinshi, na voltage ya kabiri ya 600Y/347V Wye ifite ingufu nke za H0 grounding.
Transformateur ya ZGSL-H-2500/13.2-0.6 2500 kVA irakora cyane, kandi ikwiriye gushyirwa mu nzu no hanze. Izi transformateur zifite amavuta y’ibimera ashobora kwangirika kandi zikomeza kwiyongera k’ubushyuhe bwa 65°C. Ziza zifite fuse 3 za ELSP na fuse 3 za bay-o-net zo kurinda, hamwe n’uduti 3 dufite voltage nyinshi, uduti 3 two gufata inkokora (HV)), n’uduti tune dufite voltage nkeya, buri kimwe gifite imyobo 6. Aho icyuma gishyirwamo voltage nkeya gikomezwa na Padmount plate. Byongeye kandi, transformateur ya 2500 kVA ifite switch ifite imiterere ine hamwe n’agasanduku gahindura tap gafite imyanya itanu ku ruhande rufite voltage nyinshi.
ZGSL-H-2500/13.2-0.6
ZGSL-H-2500/13.2-0.6 ni transformer ifite ubushobozi bwa 2500 kVA ifite ibice bitatu ifite urutonde rwa UL. Transformer ifite ubushobozi bwa 2500 kVA ikurikiza amahame ya IEEE C57.12.34 kandi ikurikiza amabwiriza ya DOE. Yubatswe n'ibyuma bya aluminiyumu kandi yashyizweho nk'transformer yo mu bwoko bwa loop-feed kuri sisitemu zidafite aho zihuriye n'imbere. Uburyo bwo gukonjesha bukoreshwa ni KNAN.
ZGS-Z-2500 (3050)/44/0.6
ZGS-Z-2500 (3050)/44/0.6 ni transformer yihariye ya 2500 kVA ishyirwa imbere igenewe guhaza ibisabwa byihariye by'abakiriya b'Abanyakanada na Daelim Transformer. Iyi transformer ya 2500 kVA ishyirwa hejuru ikurikiza amabwiriza ya CSA C227.4 na CAN/CSA 802.1. Ifite voltage nyinshi ya 44 kV mu buryo bwa Delta hamwe na voltage nke ya 600GrdY/347V.
Iyi transformateur ifite amavuta ya RAPO ashobora kwangirika nk'amazi akingira ubushyuhe kandi yagenewe kuzamuka k'ubushyuhe bwa 55°C cyangwa 75°C. Igipimo cya kVA ni 2500 kVA (2.5 MVA) kuzamuka k'ubushyuhe bwa 55°C na 3050 kVA kuzamuka k'ubushyuhe bwa 75°C.
ZGS-Z-2500 (3050)/44/0.6
Igitandukanya iyi transformateur ya kVA ya 2500 ni uko voltage yayo iri hasi igenewe gusohoka ku ruhande. Byongeye kandi, ibyuma bipima, imashini ihindura tap, nameplate, valve yorohereza umuvuduko, na valve yo hejuru yo kuzuza byose bishyirwa inyuma y'akazu k'imbere. Ibi bipimo bifite aho bihurira kandi bihujwe mu gasanduku k'igenzura ryo hanze ka NEMA 4. Igipimo cy'umuvuduko w'umwuka kiri hejuru y'akazu k'imbere. Agasanduku k'umuvuduko w'amashanyarazi menshi ni agasanduku k'ibumba gakozwe muri porcelain gafite imyobo ine, kandi uruhande rwa HV rufite ibikoresho bitatu bifunga inkuba, buri kimwe muri byo gitanga umupfundikizo wo kurinda insinga za MV. Byongeye kandi, ibyuma bishyushya birwanya konjesha bishyirwa mu kazu k'imbere gafite voltage nyinshi kugira ngo bikore neza.

Transformateur ya MVA 3 PH 2.5
ZGSL-Z-2500/44/4.16 (2.4) ni transformer yihariye ya 2.5 MVA ifite ibice bitatu ifite radial pad. Ingano yayo y'ibanze ya voltage ni 44.000 Delta V, mu gihe voltage ya kabiri ari 4160Y/2400 V. Transformer ifite itsinda rya DYn1 rihuza voltage nyinshi na voltage nkeya, kandi ikurikiza ibipimo bya CSA C227.4. Ifite ingufu zitangaje za 99.37%, hakurikijwe ibipimo bya CAN/CSA-802.3. Ingufu za transformer kuri 85°C ni 5.75%, kandi itanga urwego rwirindwi rw'amashanyarazi ku ruhande rwa voltage nyinshi. Ifite ubushobozi bwo gukingira amavuta bwa 2000L n'uburemere bwa kg 7500, ni igikoresho gikomeye.

Transformateur ya MVA 2.5
Igishimishije ni uko ifite igishushanyo mbonera aho ibice byombi bifite amashanyarazi maremare n'amagufi bishyirwa ku ruhande rwo kuyishyiraho, aho igice gifite amashanyarazi manini gifite icyumba cy’umwuka gishyirwa neza kikagera ku gice cyo hasi cyacyo. Kuba hari ibyuma bifunga ibikoresho n'ibindi bikoresho bishyirwa ku rukuta rw'inyuma rw'ikigega cya lisansi byongera ubushobozi bwo kuyibona no korohereza abantu kuyikoresha, bikaba bigaragaza imiterere ya transformer ikozwe neza.

Transformer ifite 2550 kVA
ZGSL-H-2550/34.5/0.415 ihagarariye transformer ikomeye ifite imiterere itatu y’urukiramende, ifite ingufu zitangaje za 2550 kVA. Irakomeye cyane ifite ubushobozi bwo gukoresha voltage nyinshi ya 34.5 kV mu gihe itanga voltage nkeya ya 415Grd/240V. Ikigaragara ni uko imiyoboro yayo ya voltage nyinshi (HV) na voltage nkeya (LV) yakozwe neza cyane muri aluminium. Iyi transformer ifite amanota meza ya 99.4% kandi ikurikiza neza amahame ya IEEE Std C57.12.34. Byongeye kandi, gushyiramo switch ifite imyanya ine yo guhagarika umutwaro byongera cyane imikorere n'umutekano.

Transformateur ya 2550 kVA
Transformateur ya 2550 kVA ikoresha sisitemu yo gukonjesha ya ONAN/ONAF, bityo ikaba irimo abafana benshi. Iyo ikora mu buryo bwo gukonjesha bwa ONAN, transformateur ifite igipimo cy'ingufu cya 2550 kVA. Ariko, uburyo bwo gukonjesha bwa ONAF bushobora kwihanganira igipimo cy'ingufu cya 3300 kVA. Ikigaragara ni uko transformateur ifite igipimo cy'ubushyuhe bw'amavuta gifite aho kivugira kandi ihujwe n'akabati gato k'icyuma kitagira umugozi ka 304. Iyi miterere yemerera kugenzura imikorere ya transformateur kure.
Uruhererekane rwa ZGSL-H-2550/34.5/0.415 rugizwe n'ibice bine, byagenewe abakiriya b'Abanyamerika kandi byashyizwe ku rutonde rwa UL kugira ngo byuzuze amahame agenga umutekano n'ubuziranenge.
ZGSL-H-2550/12.47/0.415
Uruhererekane rwa ZGSL-H-2550/12.47/0.415 rugizwe n'itsinda rya transformers 2550 kVA zakozwe na JZP Transformer ku bakiriya b'Abanyamerika. Izi transformers zo mu bwoko bwa pad-mounted kandi zifite imiterere ya loop feed. Ibisobanuro by'ingenzi by'izi transformers birimo switch ifite imyanya ine yo gushyiramo load-break, tap changer ifite imyanya itanu, gauges ifite feature idakoraho, fiyuzi eshatu za bay-o-net, na fiyuzi ebyiri zigabanya umuvuduko w'amashanyarazi.

Transformateur ya 12.47 kV 2550 kVA
Ku ruhande rw'amashanyarazi make, hari agace gafata umwanya wo gushyigikira icyuma. Amavuta yo gukingira akoreshwa ni amavuta ya ASTM II, afite ubushobozi bwa litiro 440. Ikigega cyagenewe kwihanganira igitutu ntarengwa cya PSI 10 n'igitutu cya PSI 8. Igipimo cy'amazi gikomeza kuba kuri santimetero 10 uvuye hejuru y'umwobo w'intoki kuri 25℃, hamwe n'impinduka z'urwego rwa santimetero 0.4 kuri 10℃. Ikigega cyagenewe kuzuza vacuum ya PSI 7 kandi gifite amanota 2550 kVA iyo gikoreshejwe ingufu kuri volts 11.847 hamwe n'icyuma gihindura imyobo kiri mu mwanya wa volts 124.700 ku muvuduko wa kabiri wa 415Y/240. Izi transformateur nta rugero rwa PCB rugaragara (munsi ya 2 ppm) mu gihe cyo gukora, bigamije umutekano w'ibidukikije n'uko bikurikiza amategeko.

Transformer ya 13.2 kV 2550 kVA
Transformateur ya 2550 kVA ni transformateur yakozwe byihariye ifite urutonde rwa UL, ihamya ko yubahiriza amahame akomeye y’umutekano n’ubuziranenge. Itsinda ry’itumanaho ry’iyi transformateur ni Dy1·Dd0, itanga uburyo bubiri butandukanye bwo guhuza ingufu z’amashanyarazi make:
Ku bijyanye n'umuyoboro wa Wye wa 4160V, terminals zirimo X1B, X2B, X3B zo guhuza ibice, X1A, X2A, na X3A zo guhuza ibice bitagira aho bibogamiye. Ku bijyanye n'umuyoboro wa Delta wa 2400V, terminals ni izi zikurikira: C1B kuri X2A, X2B kuri X3A, na X3B kuri X1A.

Transformer ya 24.94 kV 2550 kVA
Transformateur zose za 2550 kVA zometseho pad muri uru ruhererekane zubatswe kugira ngo zihuze n'ibipimo bya IEEE C57.12.34, zizeza ubwiza n'imikorere yo mu rwego rwo hejuru. Zifite imiterere y'umuhogo wo ku ruhande kugira ngo zihuzwe na voltage nke, bityo zigahuzwa neza na switchgear. Byongeye kandi, switch yo guhagarika umutwaro kuri izi transformateur za 2550 kVA yakozwe mu buryo butangaje mu cyumba cy'imbere gifite umuvuduko muto, itanga imyanya ine yo gukoresha mu buryo butandukanye. Imashini ihindura tap itanga imyanya itanu, kandi ibikoresho byo guhindura umuvuduko biri kuri 24.94 ± 2 × 2.5% kugira ngo bigenzurwe neza. Impedance y'izi transformateur kuri 85 ° C ni 5.87%, bigatuma zikora neza kandi neza. Byongeye kandi, urwego rwazo rwo gukingira umuvuduko mwinshi n'urudaca (BILs) rufite voltage nkeya (BILs) ruri kuri 125kV na 30kV, kugira ngo zigenzure imikorere myiza yo gukingira umuvuduko.
Baza ubu ngubu!
Ku bibazo bijyanye n'ibicuruzwa byacu cyangwa urutonde rw'ibiciro, tubwire imeri yawe maze tuzakwandikira mu masaha 24.