Leave Your Message

Transformers 500kVA zifite imiterere myiza cyane zo mu nganda zikoresha 500kVA

Transformer ifite 500kVA Three-Phase Pad-Mounted Pad ni igikoresho gikwirakwiza ingufu z’amashanyarazi gikoreshwa mu buryo bunoze cyane cyagenewe pariki z’inganda, amazu y’ubucuruzi, n’imishinga y’ibikorwa remezo. Ihindura voltage iri hagati (11kV) ikaba voltage iri hasi (400V) ikoresheje cooling immersed peterol (ONAN), bigatuma iba nziza cyane mu gushyiramo ingufu hanze. Iyi transformer ihuza uburyo bwo kwizerwa, kudakora neza, no gukoresha imbaraga nyinshi kugira ngo itange ingufu zihamye mu bidukikije.

    Ibiranga imiterere

    Core
    Imirongo y'icyuma cya silikoni ikoze mu buryo bukonje: Ifite ubushobozi bwo kwinjira cyane hamwe n'ubushyuhe buvanzwe n'amazi kugira ngo igabanye igihombo cy'umuyoboro w'amazi.
    Imiterere y'amaguru atanu y'icyiciro cya gatatu: Igabanya impedance ya zero-sequence kandi igahagarika harmonics.
    Ese?Ingufu
    Gufunganya ingufu nyinshi: Gupfunyika icyuma gikozwe mu muringa gikoresheje impapuro za Nomex kugira ngo gishobore kwihanganira ingufu nyinshi.
    Gufunga Voltage nke: Imiterere y'icyuma gifite urwego rwinshi kugira ngo kirusheho kugira imbaraga zo guhangana n'amashanyarazi make.
    Ese?Ikigega n'Ubukonje​
    Amababa ya radiateri ya korrugated: Gukonjesha kwa convection karemano nta mafeni yo hanze.
    Igishushanyo mbonera gifunze neza: Kirinda ogisijeni n'ubwandu bw'amavuta.
    Ese?Sisitemu yo gukingira ubwirinzi​
    Amavuta y'ubutare (asanzwe) cyangwa amavuta ya ester ya FR3 (arengera ibidukikije), atanga ubushyuhe, ubukonje, no kuzimira burundu.
    Igipimo cy'ibisohoka mu mubiri ≤50pC (IEC 60076 yujuje ibisabwa).
    Transformer yo mu bwoko bwa Cooper Oil Immersed Frequency 10001Transformer yo mu bwoko bwa Cooper Oil Immersed Frequency 10002Transformer yo mu bwoko bwa Cooper Oil Immersed Frequency 10003
    Transformers-500kVA-Ifite Ingano Eshatu-Ifite Ingufu-Nyinshi-Ku Nganda
    • Transformers-500kVA-Zifite Ingufu Zitatu-Zifite-Ingufu-Nyinshi-Ku Nganda (1)
    • Transformers-500kVA-Zifite Ingufu Zitatu-Zifite-Ingufu-Nyinshi-Ku Nganda (2)
    • Transformers-500kVA-Zifite Ingufu Zitatu-Zifite-Ingufu-Nyinshi-Zifite-Ingufu-Ku-Inganda (3)
    • Transformers-500kVA-Zifite Ingufu Zitatu-Zifite-Ingufu-Nyinshi-Ku Nganda (4)
    • Transformers-500kVA-Zifite Ingufu Zitatu-Zifite-Ingufu-Nyinshi-Zifite-Ingufu-Nyinshi-Ku Nganda (5)
    • Transformers-500kVA-Zifite Ingufu Zitatu-Zifite-Ingufu-Nyinshi-Ku Nganda (6)
    Transformer y'amavuta ya Cooper01

    Porogaramu

    Pariki z'inganda
    Ikoresha imashini ziremereye, imiyoboro y'imashini zikora (urugero, imashini zicapa, cranes), kandi igashyigikira imitwaro myinshi y'igihe gito.
    Ese?Inyubako z'ubucuruzi​
    Ikwirakwiza ingufu z'amashanyarazi zo gukoresha amatara, sisitemu za HVAC, ascenseur, n'umutekano mu maduka, amahoteli, n'ibiro.
    Imishinga y'ibikorwa remezo
    Sitasiyo za gari ya moshi, inganda zitunganya amazi yanduye, n'amashanyarazi yo ku kibuga cy'indege.
    Ese?Kuvugurura imiyoboro y'amashanyarazi mu cyaro
    Isimbura transfoma zishaje kugira ngo yongere ubwizerwe no gukoresha neza ingufu.

    Ibyiza by'ingenzi

    Kwizerwa cyane​
    Itsinda ibizamini bya IEC 60076 byo kwihanganira amashanyarazi make, bishimangira ko ihamye mu gihe cy'ikosa ry'urukuta rw'amashanyarazi.
    Ikigega gifunze neza cyongera igihe cyo kubaho cy'amavuta (kidakoreshwa mu kubungabunga kugeza ku myaka 10).
    Ese?Gukoresha neza ingufu
    Igihombo gito cy'umuzigo kigabanya ikiguzi cy'imikorere, byubahiriza amahame ya IEEE C57.12.
    Ese?Guhuza n'ibidukikije​
    Ikora mu bushyuhe bukabije (-40℃ kugeza +55℃) no mu misozi miremire (≤3,000m).
    Amahitamo y'ubwenge
    Ishyigikira guhuza IoT na sensors z'ubushyuhe, monitors z'urwego rw'amavuta, n'amakuru ahamagara ari kure.

    Igenzura ry'Ubuziranenge

    Buri gice gikorerwa isuzuma rikomeye, ririmo:
    Ibizamini byo kwirinda gushyushya no gupima ingufu z'amashanyarazi.
    Ibipimo byo gutakaza imizigo no gupima igihombo kidasaba umutwaro.
    Igenzura rya "short-circuit" rishobora kwihanganira.
    Ibyemezo byatanzwe na ISO 9001, ISO 14001, na KEMA byerekana ko bikurikiza amategeko mpuzamahanga.

    Amabwiriza agenga guhitamo

    Ibisabwa ku mutwaro​
    Umutwaro Uhoraho: Hitamo transfoma zifite amanota ≥125% y'umutwaro ntarengwa witezwe (urugero, 500kVA ku ikoreshwa rya 400kVA rihoraho).
    Gutwara ibintu byinshi mu gihe gito: Ibikorwa by’inganda bishobora gusaba ubushobozi bwo gutwara ibintu 150% mu minota 30.
    Ese?Imiterere y'ibidukikije
    Ubushuhe/Umunyu: Uturere two ku nkombe dukenera irangi ririnda ingese.
    Ibisabwa mu mwanya: Menya neza ko hari ahantu harenga metero 1.5 hafi ya transformateur kugira ngo hakorwe neza.
    Ese?Gukurikiza amategeko
    Ihuye na IEC 60076, IEEE C57.12, GB 1094 (Ubushinwa), na ATEX ku bidukikije biteje akaga.
    Ese?Guhitamo amavuta
    Amavuta y'ubutare: Ahendutse ku bidukikije bisanzwe.
    Amavuta ya Ester ya FR3: Arinda umuriro kandi ntangiza ibidukikije ku bice by’ingenzi (urugero, aho amakuru aboneka).

    Gushyiraho no kubungabunga

    Gushyiramo
    Koresha umusingi uringaniye ufite ubushobozi bwo guhangana n'ubutaka bwa ≤4Ω.
    Imiyoboro y'insinga ishyigikira insinga za 185mm² (injira hasi cyangwa ku ruhande).
    Ese?Gutunganya ibikorwa bisanzwe​
    Buri gihembwe: Reba urwego rw'amavuta, ibara, n'aho amazi ava.
    Buri mwaka: Gerageza ubushobozi bwo kwirinda gushyushya (megohmmeter 2,500V) kandi ukore isesengura rya chromatography y'amavuta.
    Gukemura ibibazo
    Gushyuha cyane: Genzura uburyo radiator iziba cyangwa ibintu bidasanzwe biziba.
    Gusohora igice cy'amazi: Koresha chromatography y'amavuta kugira ngo umenye inenge z'imbere mu mubiri.
    Transformer y'amavuta ya Cooper02Transformer y'amavuta ya Cooper03Transformer y'amavuta ya Cooper04Transformer y'amavuta ya Cooper05

    Kuki twahitamo

    JIEZOU POWER, umuhanga mu by'ubuhanzi, umwuga mu gukora no gushyiraho uburyo bw'amashanyarazi ku Isi, yashinzwe mu 1989, ifite ubuso bwa metero kare 200.000.
    JIEZOU POWER, icunga cyane imishinga y’amashanyarazi, 500KV EPC, 230KV amashanyarazi akomoka ku mazi, sitasiyo y’amashanyarazi ya 115KV, n'ibindi.
    Uruganda rwa JIEZOU POWER rushobora gukora transformateur yo gukwirakwiza amavuta n'ubwoko bw'amavuta yumye, transformateur y'amashanyarazi ya 500KV 480MVA ifite ubushobozi bwo hejuru, GIS, switchgear, substation, hashingiwe ku gipimo cya ANSI/IEEE/DOE2016/CSA/IEC60076.
    JIEZOU POWER yabonye icyemezo cya ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. Kugeza mu mwaka wa 2023, ibigo n'inganda ku isi yose bikwirakwizwa muri Leta Zunze Ubumwe za Amerika, Kanada, Dubai, Repubulika ya Dominikani, Filipine, inganda n'ibigo by'ishami ry'Ubushinwa biri mu mujyi wa BengBu, umujyi wa FengYang, umujyi wa HaiAn, umujyi wa TaiZhou, umujyi wa SuZhou, umujyi wa ShenYang, umujyi wa FoShan.
    Mu kureba ahazaza, intego ya JIEZOU POWER ni ukuba umutanga serivisi z’ingufu wizewe cyane, gukemura ibibazo byihutirwa cyane ku Isi mu gucunga ingufu, kwihutisha impinduka ku isi mu ngufu zisubiramo. Kugira ngo buri wese agire ubuzima bwiza kandi bufite ubwiza buciriritse. Kugira ngo tubigereho, tuzakora ibishoboka byose kugira ngo dushyiremo imbaraga.
    Transformer y'amavuta ya Cooper06Transformer y'amavuta ya Cooper07Transformer y'amavuta ya Cooper08Transformer y'amavuta ya Cooper09

    Baza ubu ngubu!

    Ku bibazo bijyanye n'ibicuruzwa byacu cyangwa urutonde rw'ibiciro, tubwire imeri yawe maze tuzakwandikira mu masaha 24.

    Leave Your Message