Leave Your Message

Transformer ifite inkingi imwe—50kVA

Ingano z'ibanze z'amashanyarazi: 13.8 kV/12.47kV/2.4/7.2kV/14.4kV/24.94kV/34.5kV/27.6kV,n'ibindi
Ingano ya Voltage ya Kabiri: 120/240V; 240/480V; 347/600Y; 277V; 347V
URUGERO RW'IBIHANGANO BYA HV: 2280-36225V
UBWOKO BW'IHURIRO: Ii0/Ii6
UBWOKO: Isanzwe/CSP
YARI: 30-150kV
Amahame ngenderwaho: IEEE/ANSI/CSA/IEC/DOE
Porogaramu: Ikwirakwizwa, Imiterere

    Ibisobanuro by'igicuruzwa

    Transformer ya JZP Transformer ifite uburebure bwa kVA 50, yemejwe ko ifite urutonde rwa UL kandi ishyigikiwe na raporo y'igenzura rya CESI. Ifite uburebure bwa voltage bwa 2.4-34.5kV, transformer ikurikiza amahame mpuzamahanga atandukanye nka ANSI, IEEE, CSA, IEC, na DOE, igenzura ko ihura n'imikorere n'imikorere ku isi yose. Ikoresheje uburambe bw'imyaka 20 mu gushushanya no kohereza mu mahanga, itsinda rya JZP Transformer rifite ibikoresho byo guhaza ibisabwa bitandukanye, ritanga ibisubizo bihinduka ku bahinduramo badasanzwe. Ifite ubushake bukomeye bwo kunyurwa n'ubwiza bw'abakiriya, JZP Transformer itanga ibicuruzwa byizewe, byiza kandi bitekanye kugira ngo bihuze n'ibyo abakiriya bakeneye ku isi yose bakeneye.
    Transformer ifite inkingi imwe—37
    Transformer ifite inkingi ya 13.8 kV ifite 50 kVA
    D-50-13.8/0.12-0.24kV, transformateur ifite inkingi ya 50 kVA, yakozwe neza na JZP Transformateur, ikurikije amahame ya IEEE C57.12.20. Ifite ubushobozi bwa 50kVA, ikora kuri 13.8 kV ku ruhande rw'ibanze kandi itanga 120/240V ku ruhande rw'inyongera. Transformateur ifite imiyoboro ibiri ifite amashanyarazi menshi, imiyoboro itatu ifite amashanyarazi make, n'imiyoboro ibiri igabanya imikorere n'umutekano.

    JZP Transformer ihamya ko ifite ireme kandi yizewe muri buri gikoresho. Transformateurs zakozwe kugira ngo zihuze n'ibikenewe byihariye by'umuyoboro w'amashanyarazi wa Guyana, zigatanga amashanyarazi neza kandi ahoraho. Ifite ubushake bukomeye bwo guhaza abakiriya, JZP Transformer itanga ibicuruzwa byiza na serivisi nziza cyane kugira ngo ihuze n'ibyo ikigo gikeneye muri Guyana.
    13
    Transformer y'icyiciro kimwe ya 14.4 kV 50 kVA
    D-50-14.4/0.12-0.24 ni transformateur ifite inkingi imwe ya 50 kVA. Ikora kuri 24940/14400V (voltage nyinshi) na 120/240V (voltage nkeya) ifite icyuma kimwe cya HV. Transformateur ifite aluminium winding ihuye n'ibipimo ngenderwaho bya CSA C2.1 na CSA 802.1. Ikora kuri 60Hz kandi ikoreshwa muri sisitemu yo gukonjesha ya ONAN. Transformateur ni insulation yo mu rwego rwa A.
    14
    Transformer imwe ya 16/27.6kV 50 kVA
    D-50-16-27.6kV/347(600Y)V ni transformer yihariye ya 50 kVA ifite inkingi imwe, yagenewe gukoreshwa mu buryo bwihariye. Ikora ku gipimo cy'amashanyarazi cya 16kV na 27.6kV, itanga ingufu nke kuri 347(600Y)V.
    Yakozwe kandi ikorwa na JZP Transformer, ikurikiza amahame akomeye ya CSA C802.1 na CSA C2.1, igenzura imikorere myiza n'umutekano. Transformer itanga amahitamo abiri ya voltage nyinshi: 16,000V na 27,600V, bigatuma ikoreshwa mu buryo butandukanye mu gukwirakwiza ingufu. Ifite bushing ifite voltage nyinshi, bushing ebyiri za voltage nke, na switch ya voltage ebyiri kugira ngo byoroshye guhitamo voltage.
    Ubushobozi bwihariye bw'iyi transformer ifite ingufu ebyiri ya 50kVA ifite amashanyarazi adasanzwe mu karere, ikaba ifasha mu gutanga amashanyarazi yizewe kandi ikujuje ibisabwa mu nganda.
    1627
    Transformer y'icyiciro kimwe ya 2.4kV 50 kVA
    D-50-2.4kV/120 (240)V ni transformer ifite inkingi ya 50 kVA, ifite urwego rumwe, ifite voltage nyinshi ya 2.4 kV na voltage nkeya ya 120V, yagenewe umukiriya w’Umunyakanada. Buri transformer ifite bushing imwe ifite voltage nyinshi n’uduce dutatu dufite voltage nkeya, bigatuma ihuza neza. Yakozwe neza kandi igakorwa neza, izi transformer zujuje ibisabwa bya CSA, zigatanga imikorere myiza n’umutekano. Kubera ko zishishikajwe no kuba indashyikirwa, izi transformer zakozwe kugira ngo zihuze n’ibyo umukiriya w’Umunyakanada akeneye, zigatanga ingufu zizewe kandi zikubahiriza amabwiriza yose akenewe mu nganda.
    2

    Baza ubu ngubu!

    Ku bibazo bijyanye n'ibicuruzwa byacu cyangwa urutonde rw'ibiciro, tubwire imeri yawe maze tuzakwandikira mu masaha 24.

    Leave Your Message