Leave Your Message

Transformer ifite inkingi imwe—37.5 kVA

Ingano z'ibanze z'amashanyarazi: 2.4-34.5 kV
Ingano ya Voltage ya Kabiri: 120/240V; 240/480V; 347/600Y; 277v;
URUGERO RW'IBIHANGANO BYA HV: 2280-36225V
UBWOKO BW'IHURIRO: Ii0/Ii6
UBWOKO: Isanzwe/CSP
YARI: 30-150kV
Amahame ngenderwaho: IEEE C57.12.20, ANSI C57.12, DOE 2016, CSA C2.1 na 2.2 na CSA C802.1
Porogaramu: Ikwirakwizwa, Imiterere

    Ibisobanuro by'igicuruzwa

    JZP ni ikigo gikomeye mu gukora transformateur zemewe na CSA, UL, na cUL. Bafite ubuhanga mu gukora transformateur nziza ya 37.5 kVA ifite inkingi imwe yujuje ibisabwa na ANSI, CSA, IEEE, DOE, na IEC. Izi transformateur zagenewe gukoresha ibintu bitandukanye, harimo serivisi zitanga serivisi, uturere tw’icyaro, na sisitemu yo gukwirakwiza ingufu z’amashanyarazi. Kubera ko zishishikajwe no kugira ubuziranenge n’ubwizerwe, transformateur za JZP zizewe mu mikorere myiza no gukora neza, bigatuma ziba amahitamo meza ku bikenewe mu bijyanye n’amashanyarazi bitandukanye.
    JZP Transformer itanga transformer ifite ubushobozi bwo gukora ibintu bitandukanye ya 37.5 kVA ijyanye n'amahame mpuzamahanga atandukanye kandi ishobora guhindurwa kugira ngo ihuze n'ibisabwa bitandukanye. Transformers zacu zoherejwe neza mu bihugu byinshi, birimo Leta Zunze Ubumwe za Amerika, Kanada, Panama, Venezuwela, na Honduras.
    Dufite ubushobozi bwo gukora ibikoresho birenga 500 buri kwezi, twizeza ko igihe cyo kubitanga cyihuse kigera ku byumweru 5-8. Umuhango wacu wo gukora ibintu byiza urenze ibyo gukora, kuko dufite amatsinda y’inzobere mu gushyiraho no kubungabunga ibikoresho nyuma yo kugurisha muri Amerika. Ibi bituma ibibazo byose ushobora guhura nabyo bikemurwa vuba kandi bigakemurwa.
    Waba uri ikigo cy’ibigo by’imari n’imigabane, ucuruza transformer, cyangwa umwubatsi, ushobora kugura transformer ya JZP ifite inkingi imwe ufite icyizere, uzi neza ko ushora imari mu gicuruzwa cyizewe kandi cyemewe. Menya neza kandi wizewe na JZP Transformer, yagenewe ibyo ukeneye byihariye.
    Transformer ifite inkingi imwe—37
    Transformer ya 37.5 kVA 13.8 kV
    Iyi transformer ya DL-37.5/13.8/0.24 (0.12), ni transformer ifite inkingi imwe ikozwe na JZP Transformer, ikoreshwa hakurikijwe amabwiriza ya IEEE n'amahame ngenderwaho ya DOE 2016. Iyi transformer ifite ubushobozi bwa 37.5kVA, ifite voltage nyinshi ya 13800V n'umusaruro muto wa voltage ya 240 (120) V. Uburyo bwayo bwo guhuza ni Ii0, ifite imiterere ya polarity ya subtractive.
    Yagenewe abakiriya b'Abanyamerika by'umwihariko, DL-37.5/13.8/0.24(0.12) itanga imikorere myiza n'ubwizerwe bidasanzwe. Kubera ubuhanga bwa JZP mu gushushanya no gukora transformateur, ushobora kwizera transformateur iguhaza ibyo ukeneye neza.
    37
    Transformer ya 37.5 kVA 14.4 kV
    DL-37.5/14/0.347, ni transformer ifite inkingi imwe. Iyi transformer yujuje ibisabwa na IEEE kandi ifite ubushobozi bwa 37.5 kVA. Ifite icyuma gikoresha ingufu nyinshi, ibyuma bibiri bifite ingufu nke, n'icyuma gihindura amatafari gifite imyanya 5, bigatuma habaho imikorere myiza kandi ikora neza.
    37
    Transformer ya 37.5 kVA 19.9 kV
    DL-37.5/19.9/0.24 (0.12), ni transformer ifite inkingi. Ifite voltage iri hejuru ya 19920V, ifite ibyuma bibiri bifite voltage iri hejuru n'ibyuma bitatu bifite voltage iri hasi, bituma ingufu zikwirakwira neza.
    Iyi transformateur nziza cyane ifite uburebure bwa silinda yakozwe neza cyane kugira ngo ikore neza kandi yiringire cyane. Ni transformateur ifite uburebure bwa 37.5kVA yubatswe ku buryo ihuye n'ibipimo bya ANSI C57.12 bikomeye, ihamya imikorere myiza n'umutekano.
    37

    Baza ubu ngubu!

    Ku bibazo bijyanye n'ibicuruzwa byacu cyangwa urutonde rw'ibiciro, tubwire imeri yawe maze tuzakwandikira mu masaha 24.

    Leave Your Message