Transformer ifite 2000kVA ifite ibice bitatu
Ibisobanuro by'igicuruzwa
Transformers za JZP Transformer za 2000kVA, 34.5kV zishyirwa kuri pad zishyirwa muri Sisitemu yo kubika ingufu za Bateri (BESS) mu Karere ka Kern, muri Kaliforuniya, aho zitanga ingufu zizewe zo gufasha ibikoresho bitandukanye biri muri sitasiyo yo kubika ingufu. Zarangiye muri Gicurasi 2024 zigashyikirizwa abakiriya b'Abanyamerika, izi transformers ni ingenzi mu gutuma habaho imikorere idahinduka no gucunga neza ububiko bw'ingufu.
01020304050607
| Ubushyuhe buri hagati y'ikirere | Ubushyuhe bugera kuri -15.0°C, Ubushyuhe ntarengwa 41.0°C, Ubushyuhe bw'amasaha 24 ntarengwa 33.0°C |
| Uburebure | |
| Imiterere y'imitingito: | Icyiciro cy'ibyago: II, Icyiciro cya D cy'urubuga |
| SS = 1.28 g, S1 = 0.43 g, SMS = 1.54 g, SM1 = 1.09 g, SDS = 1.03 g, SD1 = 0.73 g |
| Imikorere y'izina (itsinda kuva ku cyiciro kugeza ku kindi) | 34.5kV |
| Imikorere ntarengwa (ishyirwa ku cyiciro) | 38kV |
| Imiterere y'izunguruka | Delta |
| Igipimo cya Bushing | 600A |
| Ubwishingizi bw'ingufu | 200kV BIL |
| Ubwishingizi bw'ibihuru | 200kV BIL |
| Ubunini bwa Bushing | Gatandatu (Ifunguro rya Loop) |
| Guhangana n'urujya n'uruza rw'amashanyarazi rugufi | 30kA |
| Kuramo | LBOR Switch |
| Kuramo ingano y'imashini zisimburana | Icyiciro kimwe (1) cya 3 |
| Imikorere y'izina (itsinda kuva ku cyiciro kugeza ku kindi) | 480V |
| Imiterere y'izunguruka | Wye ishingiye ku butaka |
| Ubwikorezi bwo gukingira no gukingira imigozi BIL | IMODOKA YA 30KV |
| Guhangana n'umuvuduko mugufi | 65 kA* |
| Umwobo w'isukari ya LV ufite ubunini | (8) NTABWO HARI UMWUBO 2 |
| Ikintu gisanzwe cyo gushyuha cyane | 110% |
| Ubudahangarwa bushingiye ku ihame | Oya |
| Bisi yo munsi y'ubutaka | Yego |
| Voltage y'amashanyarazi ya serivise yo kugenzura | AC 277V |
| Ibipimo by'ikinyabiziga gikoresha amashanyarazi | Urutonde rwa UL |
| Bikwiriye kwinjira muri serivisi | Yego |
| Igipimo (muri) | Ubushyuhe: 83.9*94.7*95.3 |
| Ikigega n'ibikoresho | ibiro 4,630 |
| Amavuta y'ingano | Galoni 900 |
| Uburemere bwose | ibiro 21,600 |
Ibintu by'ingenzi n'inyungu
Gukwirakwiza neza ingufu mu bubiko bw'ingufu
Transfoma za 2000kVA zagenewe kuva kuri Voltage Medium (MV) zikajya kuri Voltage Low (LV), bigatuma ziba nziza cyane mu guhuza na switchboards muri sisitemu yo kubika ingufu. Iyi imiterere yo kumanuka ni ingenzi kugira ngo ingufu zikwirakwizwe neza kandi zizewe ku bikoresho by'inyongera, bishyigikira imikorere myiza y'ibikorwa remezo bya BESS.
Gukonjesha birambye kandi bihendutse
Mu rwego rwo kubahiriza intego ya JZP Transformer yo kubungabunga ibidukikije, transformers zikoresha amavuta ashobora kubora nk'amazi akonjesha. Iyi solution ntitanga gusa ubushobozi bwo gukingira ibidukikije ahubwo inashyigikira gukoresha neza ingufu.
Kuramba no Kurinda Umutekano Byubatswemo
Udukingirizo twa NEMA 3R: Transformateur zacu zibikwa mu dukingirizo tw’amashanyarazi twa NEMA 3R twirindwa imvura, urubura, kandi turinda urubura, hamwe n’imiyoboro y’amazi yubatswemo. Udukingirizo dutanga uburinzi bukomeye ku bidukikije, turinda ibice by’amashanyarazi by’imbere kandi tugakomeza kuramba nubwo haba hari ibidukikije bikomeye.
Ibiranga Kurwanya Uburiganya n'Umutekano: Byakozwe hashingiwe ku mutekano, transfoma zifite uburyo bwo kuzifunga no kuzifunga kugira ngo hirindwe ko abantu batabigeraho cyangwa ngo babikoreho, bigabanya ibyago byo kwibwa no gukora neza igihe cyose.
Igishushanyo mbonera cyoroshye gukoresha kugira ngo gikoreshwe mu mutekano no mu buryo bwiza
Uruhande rwa transformateur rufite voltage nkeya rufite igishushanyo cyihariye gishyizwe ku ruhande gifite umuhogo woroshye wo guhuza na switchboard. Ibipimo byo hanze, valves z'icyitegererezo, na sisitemu zo gusohora amazi biri mu kabati gashobora gufungwa gafite ingufuri eshanu. Iyi miterere idasanzwe yemerera abakoresha kugenzura neza urugero rw'amavuta, kugerageza ibipimo, no gukora imirimo yo kubungabunga batitaye ku bipimo byo hejuru (HV) cyangwa hasi (LV), birushaho kongera umutekano n'imikorere myiza.

Ibipimo byo hanze bya transformer bishyirwa kuri pad
Igenzura rigezweho n'amatangazo yo kuri interineti
Kugira ngo ikore neza kandi ikomeze gukora neza, transformateur ifite ibimenyetso by'ubushyuhe n'urugero rw'amavuta bifite aho bihurira n'aho bikorerwa kugira ngo bigenzurwe kure. Ibi bimenyetso bitanga amakuru y'igihe nyacyo ku bakoresha, bikohereza ibimenyetso by'inyongerera igihe urugero rw'amavuta ruri hejuru cyane cyangwa hasi cyane. Byongeye kandi, niba ubushyuhe bw'amazi akonjesha burenze 85°C, sisitemu izatera inyongerera. Iyo ubushyuhe buzamutse burenga 105°C, transformateur izivana ku murongo w'amashanyarazi mu buryo bwikora kugira ngo hirindwe ubushyuhe bwinshi n'ibyangirika, bityo ikomeze kurinda umutekano n'ubwirinzi bw'iyi sisitemu.

Ubwiza n'Iyubahirizwa ry'Amategeko
JZP Transformers zikorwa hakurikijwe amabwiriza akomeye mu nganda, harimo UL, ANSI, IEEE, na NEMA, zigatuma habaho imikorere myiza, kwizerwa, n'umutekano. Icyerekezo cyacu cyo gukora ubuziranenge n'udushya gihamya ko buri transformer yubatswe ku bipimo byo hejuru, itanga serivisi yizewe mu gihe cyose ibikoresho bimara.