+86 18068001229 01
Transformers z'amavuta za 220kVA zikora neza cyane mu gukoresha ibintu bikomeye
Ibiranga imiterere
Core
Imirongo y'icyuma cya silikoni ipfundikiye ikora neza kandi ikora neza ifite ubushobozi bwo gukingira ikirere kugira ngo igabanye igihombo cy'umugezi wa eddy.
Igishushanyo mbonera cy'amaguru atanu cy'icyiciro cya gatatu kugira ngo kigabanye impedance ya zero-sequence no gukumira harmonics.
Ese?Ingufu
Gufunganya ingufu nyinshi: Gupfundika icyuma gipfundikiye gifite icyuma gikingira ibyuma cya Nomex.
Gufunga Voltage nke: Imiterere y'icyuma gifite urwego rwinshi kugira ngo kirusheho kugira imbaraga zo guhangana n'amashanyarazi make.
Ese?Ikigega n'Ubukonje
Igishushanyo cya ONAN gifite amavuta akwirakwira mu buryo bw'umwimerere kandi nta mafeni yo hanze, ni cyiza cyane mu gushyira hanze.
Amababa ya radiateri ya korrugated ashyizwe mu kigega kugira ngo ubushyuhe bushire neza.
Ese?Sisitemu yo gukingira ubwirinzi
Amavuta y'ubutare (cyangwa amavuta ya ester adahumanya ibidukikije) atanga ubushyuhe, ubukonje, no kuzimira burundu.
Igipimo cy'ibisohoka mu mubiri ≤50pC (IEC 60076 yujuje ibisabwa).




Porogaramu
Gukwirakwiza ingufu z'amashanyarazi mu nganda
Ikwirakwizwa ry'amashanyarazi aciriritse (10kV kugeza 0.4kV) mu nganda, mu birombe, no mu nganda zikora ibyuma.
Ishyigikira umutwaro mwinshi w'igihe gito (urugero: amatanura y'amashanyarazi, amasosiyete mashya ya moteri).
Ese?Inyubako z'ubucuruzi
Gukwirakwiza amashanyarazi ku maduka manini, iminara y'ibiro, n'amahoteli.
Ese?Ibikorwaremezo
Sitasiyo za gari ya moshi, ibibuga by'indege, n'inganda zitunganya amazi yanduye.
Ese?Uduce twa kure
Ikora neza ahantu harangwa n'ubushuhe bwinshi, ivumbi, cyangwa ubushyuhe buhindagurika.
Ibyiza by'ingenzi
Kwizerwa cyane
Ikigega gifunze neza kirinda ogisijeni n'ubwandu bw'amavuta.
Ubushobozi bukomeye bwo kwihanganira umuvuduko mugufi (GB/T 1094.5 ikurikije).
Ese?Gusana bike
Igishushanyo mbonera kidasaba kwitabwaho gifite urwego rw'amavuta n'ubushyuhe mu gihe nyacyo.
Ese?Ihendutse ku giciro
Ishoramari rito ry’ibanze n’igihombo gito cy’ingufu mu mikorere.
Ese?Amahitamo adahumanya ibidukikije
Iboneka hamwe n'amavuta ya ester ashobora kubora (urugero, FR3) kugira ngo ikurikize RoHS.
Amabwiriza yo guhitamo
Buri gice gikorerwa isuzuma rikomeye, ririmo:
Ibizamini byo kwirinda gushyushya no gupima ingufu z'amashanyarazi.
Ibipimo byo gutakaza imizigo no gupima igihombo kidasaba umutwaro.
Igenzura rya "short-circuit" rishobora kwihanganira.
Ibyemezo byatanzwe na ISO 9001, ISO 14001, na KEMA byerekana ko bikurikiza amategeko mpuzamahanga.
Amabwiriza agenga guhitamo
Ibiranga Umutwaro
Emeza ubwoko bw'umutwaro (uhoraho ugereranije n'uhindagurika).
Suzuma ibisabwa mu gihe gito cyo gukoresha umutwaro mwinshi (urugero, amatanura y'amashanyarazi).
Ese?Imiterere y'ibidukikije
Ubutumburuke ≤ metero 1.000 (gufata umwanya hejuru y'aho bigeze birakenewe).
Ubushyuhe bw'ikirere: -25℃ kugeza +45℃ (ubukonje bwiyongereye mu turere dushyuha).
Ese?Gukurikiza amategeko
Ihuye na GB 1094 (Ubushinwa), IEC 60076 (mpuzamahanga), n'ibyemezo byihariye ku nganda (urugero, ATEX ku kirere giturika).
Gushyiraho no kubungabunga
Ibisabwa mu gushyiraho
Urufatiro ruringaniye rufite ahantu harenga metero ≥1 ku mpande zose kugira ngo ubushyuhe bushire.
Ubudahangarwa bwo hasi ≤4Ω; igishushanyo mbonera cyo kurinda inkuba gitandukanye.
Ese?Gutunganya ibikorwa bisanzwe
Reba urwego rw'amavuta, ibara, n'amazi ava buri mezi 6.
Gerageza uburyo bwo kwirinda gushyushya buri mwaka ukoresheje megohmmeter ya 2,500V.
Ese?Gukemura ibibazo
Gushyuha cyane: Genzura uburyo radiator iziba cyangwa ibintu bidasanzwe biziba.
Isesengura rya Chromatography y'Amavuta: Kumenya ibimenyetso bya mbere by'imyotsi yo mu nda cyangwa kwangirika kw'ubushyuhe.



Kuki twahitamo
JIEZOU POWER, umuhanga mu by'ubuhanzi, umwuga mu gukora no gushyiraho uburyo bw'amashanyarazi ku Isi, yashinzwe mu 1989, ifite ubuso bwa metero kare 200.000.
JIEZOU POWER, icunga cyane imishinga y’amashanyarazi, 500KV EPC, 230KV amashanyarazi akomoka ku mazi, sitasiyo y’amashanyarazi ya 115KV, n'ibindi.
Uruganda rwa JIEZOU POWER rushobora gukora transformateur yo gukwirakwiza amavuta n'ubwoko bw'amavuta yumye, transformateur y'amashanyarazi ya 500KV 480MVA ifite ubushobozi bwo hejuru, GIS, switchgear, substation, hashingiwe ku gipimo cya ANSI/IEEE/DOE2016/CSA/IEC60076.
JIEZOU POWER yabonye icyemezo cya ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. Kugeza mu mwaka wa 2023, ibigo n'inganda ku isi yose bikwirakwizwa muri Leta Zunze Ubumwe za Amerika, Kanada, Dubai, Repubulika ya Dominikani, Filipine, inganda n'ibigo by'ishami ry'Ubushinwa biri mu mujyi wa BengBu, umujyi wa FengYang, umujyi wa HaiAn, umujyi wa TaiZhou, umujyi wa SuZhou, umujyi wa ShenYang, umujyi wa FoShan.
Mu kureba ahazaza, intego ya JIEZOU POWER ni ukuba umutanga serivisi z’ingufu wizewe cyane, gukemura ibibazo byihutirwa cyane ku Isi mu gucunga ingufu, kwihutisha impinduka ku isi mu ngufu zisubiramo. Kugira ngo buri wese agire ubuzima bwiza kandi bufite ubwiza buciriritse. Kugira ngo tubigereho, tuzakora ibishoboka byose kugira ngo dushyiremo imbaraga.



Baza ubu ngubu!
Ku bibazo bijyanye n'ibicuruzwa byacu cyangwa urutonde rw'ibiciro, tubwire imeri yawe maze tuzakwandikira mu masaha 24.